Three thread standards compared: M-metric (top row), NPT tapered thread (middle row), and PG thread fittings (bottom row) with gauges for reference.
In over 18 years of supplying cable glands to B2B customers across Europe, the Middle East, and Asia-Pacific, the single most common cause of site returns and project delays is thread mismatch: the gland ordered has a different thread standard from the enclosure knockout. A gland with M20 metric thread cannot be installed in a ½" NPT knockout — and forced installation strips threads, destroys IP ratings, and creates safety hazards.
This guide gives procurement engineers, project managers, and site supervisors the reference they need to specify the correct thread standard every time — covering the three dominant global standards (M-metric, NPT, PG), their dimensional equivalents, the regions and industries where each dominates, and the adapter solutions available when a mismatch is unavoidable.
M-metric threads, defined by ISO 965, are the international standard for cable glands used in European-design equipment and the most widely specified thread standard globally. The designation is straightforward: M20 means 20mm nominal outer diameter with a standard 1.5mm pitch. M-metric threads are parallel (cylindrical) — the IP sealing is provided by the gland sealing ring or a separate O-ring at the enclosure face, not by the thread engagement itself.
|
Metric Size |
Cable OD Range (typical) |
Equivalent PG (approx.) |
Application |
|
M12 × 1.5 |
3–6.5 mm |
PG7 |
Instrument cables, sensors |
|
M16 × 1.5 |
4–8 mm |
PG9 |
Control cables, small signal |
|
M20 × 1.5 |
6–12 mm |
PG11/PG13.5 |
Standard power cable (2.5–10mm²) |
|
M25 × 1.5 |
10–17 mm |
PG16 |
Medium power cable |
|
M32 × 1.5 |
15–21 mm |
PG21 |
Multi-core, larger cable |
|
M40 × 1.5 |
19–28 mm |
PG29 |
Large power cable, armored |
|
M50 × 1.5 |
25–35 mm |
PG36 |
High-power armored cable |
|
M63 × 1.5 |
34–44 mm |
PG48 |
Large armored HV cable |
National Pipe Thread (NPT) is the mandatory standard for cable glands used in North American electrical equipment and UL-listed panel enclosures. NPT is a tapered thread — the thread OD increases from the tip toward the body, creating a wedging seal as the gland is tightened. This means NPT provides thread-entry sealing without a separate O-ring, but it also means NPT glands must not be over-tightened (which can crack the enclosure boss).
PG (Panzergewinde, or armored conduit thread) is a German-origin standard that was dominant in European electrical equipment through the 1990s. It is now technically superseded by M-metric under IEC standards, but vast quantities of PG-threaded enclosures remain in service and continue to be specified for replacement parts and retrofit projects. PG thread is parallel like M-metric.

|
Region |
Primary Standard |
Legacy Standard |
Notes |
|
Europe (EU) |
M-metric (ISO 965) |
PG (DIN 40430) |
PG still common in retrofit work |
|
North America |
NPT (ANSI B1.20.1) |
None |
UL/NEC mandatory for listed equipment |
|
China (domestic) |
M-metric |
None |
Export follows buyer standard |
|
Middle East |
M-metric or NPT |
None |
Depends on engineering origin (EU vs US EPC) |
|
Southeast Asia |
M-metric |
PG (older equipment) |
Growing standardization on M-metric |
|
Australia/NZ |
M-metric |
None |
AS/NZS 61439 aligned with IEC |
|
Latin America |
NPT or M-metric |
None |
US-EPC projects use NPT; EU-EPC use M-metric |
When retrofit projects require connecting M-metric glands to PG-threaded enclosures (or NPT to M-metric), adapter bushings provide a valid solution — but they must be specified carefully:
Mixed-standard orders: RFQ specifying multiple thread standards for one project accepted — single shipment consolidation available
Hot News2026-11-20
2026-11-17
2026-11-11
2026-11-02
2026-10-28
2026-10-22
Copyright © Zhejiang Hongxiang Connector Co., Ltd. All Rights Reserved - Privacy Policy